Temperature sensor TP-Exi-431_434
Product description
Sensors for temperature measurement in potentially explosive areas, made of flexible mantle thermocouple.
Technical data
| Type | Athosphere type | Temperature range | ATEX designation |
|---|---|---|---|
| TP-Exi-43X-XJ | mines | -20÷150°C | I M1 Ex ia I Ma |
| gasses | -40÷700°C | II 2G Ex ia IIC T6-T1 Gb | |
| dusts | -40÷700°C | II 1D Ex ia IIIC T85÷700° Da | |
| TP-Exi-43X-XK | mines | -20÷150°C | I M1 Ex ia I Ma |
| gasses | -40÷1100°C | II 2G Ex ia IIC T6-T1 Gb | |
| dusts | -40÷1100°C | II 1D Ex ia IIIC T85÷1100°C Da | |
| TP-Exi-43X-XN | mines | -20÷150°C | 1 M1 Ex ia I Ma |
| gasses | -40÷1250°C | II 2G Ex ia IIC T6-T1 Gb | |
| dusts | -40÷1250°C | II 1D Ex ia IIIC T85÷1250°C Da |
Technical data:
| Process connection | without or with compression gland, steinless steel 1.4541 (option) |
| Protection sheath | ∅3, ∅4.5, ∅6, ∅8mm, Inconel 600 (J, K), Nicrobell (N) |
| Sensing element | J (Fe-CuNi) insulated PN-EN 60584 class 1 |
| K (NiCr-NiAl) insulated PN-EN 60584 class 1 | |
| N (NiCrSi-NiSi) insulated PN-EN 60584 class 1 | |
| Sensor wire configuration | 1J: single thermocouple J |
| 1K: single thermocouple K | |
| 1N: single thermocouple N | |
| 2J: double thermocouple J | |
| 2K: double thermocouple K | |
| 2N: double thermocouple N | |
| Connection head | XE-DANA, IP65, ATEX II 2GD |
| XE-BE, IP65, ATEX I M2, operating temperature up to 100°C | |
| Cable gland | ATEX II GD, IP65, for cable outer diameter ∅6÷∅8 mm |
| cable gland ATEX I M2, IP65, for cable of outer diameter ∅6÷∅12 mm | |
| Ambient temperature (Tamb) | -40÷75°C |
| Maximum operating pressure | 0.1MPa |
| Response time | t0.9ca 3 s (in water 0.2 m/s for ∅3 mm), t0.9ca 14 s (in water 0.2 m/s for ∅8 mm) |
| Sensor length (L) | 100÷5000 mm (by 50 mm) |
| Optional accesories | 0: none |
| KP: compression gland | |
| T: ATEX certified temperature transmitter |